Caracterización experimental de anclajes post instalados de gran capacidad en situaciones sísmicas

  1. Emilio José Rey Bouzón 1
  2. Manuel F. Herrador 1
  3. Sindy Seara Paz 1
  4. Senén Paz Abuín
  5. Roi Meizoso Loureiro
  6. Juan Meizoso Rodríguez
  1. 1 Universidade da Coruña
    info

    Universidade da Coruña

    La Coruña, España

    ROR https://ror.org/01qckj285

Revista:
Hormigón y acero

ISSN: 0439-5689 2605-1729

Año de publicación: 2022

Número: 298

Páginas: 67-74

Tipo: Artículo

Otras publicaciones en: Hormigón y acero

Resumen

This research focuses on the development of a characterization system for large (φ32 mm), resin-bonded post-installed anchors in concrete in case of an earthquake. It is based on the tests required by ACI 355.4-11 and its conditions, proposing a new test and test design that meets these since the design proposed in the standard makes the test unfeasible. Tensile characterization tests are carried out on cracked concrete (0.3 mm crack opening), seismic tension (0.5 mm crack opening plus loading cycles) and seismic shear (0.5 mm crack opening plus loading cycles) obtaining guaranteed values (95% percentile) for reduced resistance concretes.